Reference

Section 6-3
Description A number with 4 transferred digits set with the NT600S number setting function is
reported to the Host with this command.
8-digit Number Input Notify
Format
1B
[ESC]
46
F
d
1
d
2
n
1
n
2
n
3
n
4
d
3
n
6
n
7
n
8
0D
[CR]
n
5
d
1
d
2
d
3
: Numeral memory table address to which number was input (3-digit hex-
adecimal)
000 to 1FF
H
n
1
n
2
n
3
n
4
n
5
n
6
n
7
n
8
: Input number data (8-digit BCD)
Description A number with 8 transferred digits set with the PT number setting function is re-
ported to the Host with this command.
7-3-3 Lamps and Touch Switches
Notifying the Display Status The lit/flashing status of the lamps and touch switches which are set on the screen
currently displayed on the NT600S is sent to the Host by executing the following
command.
Lamp and Touch Switch Display Status Response
Format
1B
[ESC]
n
1
n
2
m
1
53
S
n
3
m
1
: Display status
m
1
Display status
0(30
H
) Not lit (normal display)
1(31
H
) Lit
2(32
H
) Flashing inverse
n
1
n
2
n
3
: Lamp or touch switch address (3-digit hexadecimal)
000 to 0FF
H
(0 to 255)
Description The NT600S returns this command to report the lamp or touch switch number dis-
play status to the Host in response to the Lamp and Touch Switch Display Status
Enquiry Command (see
7-2-3
) sent from the Host.
Lamps 0 to 111 are reported as being lit when in the “flashing inverse” status.