386
CIP Message Communications Appendix D
The 8-bit logical address can be used for the Attribute ID. Use the Attribute ID when requesting a Service of a
particular Object of a particular device.
Example of CIP Message Creation
Setting the Route Path
Port Number
The following description explains the network port, which is used to specify the route path. In the CJ2 Series,
the Backplane is also considered part of the network when specifying the Link Address.
CPU Unit
CJ2 (Not supported by CS1/CJ1 CPU Units.)
Each CPU Unit has one backplane port. By convention, the built-in port on a CJ2H-CPU6@-EIP or a
CJ2M-CPU3@ CPU Unit functions as a CPU Bus Unit.
The Backplane port is the Backplane. CPU Unit communications routed through CPU Bus Units always travel
through the backplane.
EtherNet/IP Unit or CJ2 Built-in EtherNet/IP Port
The EtherNet/IP Unit has two ports. A CJ2 CPU Unit also has two built-in EtherNet/IP ports. One is a Back-
plane port and the other is an Ethernet port.
The Backplane port is the Backplane. Communications routed through the CPU Unit, a Special I/O Unit, or
another CPU Bus Unit always travel through the backplane.
Link Address
The Link Address is a node address on the network, which is used to specify the route path.
The method to set the Link Address is different for each network.
In the CS/CJ Series, the Backplane is also considered part of the network when specifying the Link Address.
Backplane
CPU Bus Unit or Special I/O Unit
In the CS/CJ Series, the base unit is recognized as a backplane port.
CPU Bus Units, such as the EtherNet/IP Unit, are also recognized as nodes on the backplane port.
The Link Address of a CPU Bus Unit on the Backplane is the “unit number + 10 hex.” For example, when
the unit number is 0, the Link Address is 10 hex. When the unit number is F, the Link Address is 1F hex.
The Link Address of a Special I/O Unit on the Backplane is the “unit number + 20 hex.” For example, when
the unit number is 0, the Link Address is 20 hex.
Network
EtherNet/IP
The Ethernet port’s Link Address is described by the IP address.
The IP address must be described entirely in ASCII.
For example, IP address of 192.168.200.200 will be [31] [39] [32] [2E] [31] [36] [38] [2E] [32] [30] [30] [2E]
[32] [30] [30].
Port Port Number
Backplane 1
Port Port Number
Backplane 1
Ethernet 2
Vue de la page 411
1 2 ... 407 408 409 410 411 412 413 414 415 416 417 ... 463 464

Commentaires sur ces manuels

Lynwood 14 Mar 2024 | 16:50:43

How To Create An Awesome Instagram Video About Pornstars On Adultwork British Porn Stars Xxx (Https://Qooh.Me)

Ransomes 36 HYDRO Z-CONTROL MID-16HP KAW SIDE DISCHARGE SELF PROPELLED WALK BEHIND MOWER manuales

Manuales del propietario y guías del usuario para Cortadoras De Césped Ransomes 36 HYDRO Z-CONTROL MID-16HP KAW SIDE DISCHARGE SELF PROPELLED WALK BEHIND MOWER.
Ofrecemos 1 manuales en pdf Ransomes 36 HYDRO Z-CONTROL MID-16HP KAW SIDE DISCHARGE SELF PROPELLED WALK BEHIND MOWER para descargar gratis por tipos de documentos: Manual del operador


Tabla de contenidos

Manual del Operario

1

Manuel Opérateur

1

ADVERTENCIA

2

AVERTISSEMENT

2

CONTENTS

3

INTRODUCTION

4

For use on: 930300 and 930301

6

For use on: 930302

6

For use on: 930303 and 930304

7

GENERAL INSTRUCTIONS

8

ASSEMBLY INSTRUCTIONS

10

CONTROLS

14

OPERATION OF THE MACHINE

16

LUBRICATION

18

MAINTENANCE

19

SERVICE CHART

22

HEIGHT OF CUT

23

1/2" MAX

25

HEIGHT OF CUT - VERSADECK

26

ADJUSTMENTS

27

BELT ADJUSTMENTS

29

BELT REPLACEMENT

31

VERSADECK CONVERSION

32

ENGINE SPECIFICATIONS

33

DECK SPECIFICATIONS

35

GENERAL SPECIFICATIONS

36

FASTENER TORQUES

37

RANSOMES WARRANTY

39

CONTENIDOS

42

NUMERO DE MODELO 93010X

43

NUMERO DE SERIE 93010XXXXX

43

ETIQUETAS

44

ADVERTENCIA

46

INSTRUCCIONES GENERALES

47

INSTRUCCIONES DE MONTAJE

49

CONTROLES

53

FUNCIONAMIENTO DE LA MAQUINA

55

LUBRICACION

57

MANTENIMIENTO

58

CUADRO DE MANTENIMIENTO

61

ALTURA DE CORTE

62

POSICION DE CORTE A BAJA

64

ALTURA DE LOS CILINDROS

64

ELEVADORES

64

POSICION DE CORTE ALTO DE LOS

64

CILINDROS ELEVADORES

64

MAXIMO 1/4" (63 mm)

65

AJUSTESAJUSTES

66

AJUSTE DE LAS CORREAS

68

SUSTITUCION DE LAS CORREAS

70

CONVERSION A VERSADECK

71

ESPECIFICACIONES DEL MOTOR

72

ESPECIFICACIONES GENERALES

75

Elementos de

76

HOJA DE SERVICIO

77

GARANTIA DE RANSOMES

78

SOMMAIRE

81

INTRODUCTIONINTRODUCTION

82

IMPORTANT

83

ETIQUETTES

84

ATTENTION

85

INSTRUCTIONS GENERALES

86

INSTRUCTIONS DE MONTAGE

88

COMMANDES

92

UTILISATION DE LA MACHINE

94

LUBRIFICATION

96

ATTENTION

97

ENTRETIEN

97

TABLEAU D'ENTRETIEN

100

HAUTEUR DE COUPE

101

POSITION MOTEUR DE ROUE POUR

103

COUPE BASSE

103

COUPE HAUTE

103

VERSADECK

104

REGLAGES

105

REGLAGES DE COURROIES

107

REMPLACEMENT DE COURROIE

109

CONVERSION VERSADECK

110

VANGUARD V

111

SPECIFICATIONS MOTEUR

112

SPECIFICATIONS PLATEAU

113

SPECIFICATIONS GENERALES

114

COUPLES DE SERRAGE

115

GENERALITES

116

GARANTIE RANSOMES

117





Más productos y manuales para Cortadoras De Césped Ransomes

Modelos Tipo de documento
CG161 Manual del operador   Ransomes CG161 Operator`s manual, 54 paginas
Parkway 2250 Plus Instrucciones de operaciones       Ransomes Parkway 2250 Plus Operating instructions, 132 paginas
CG161 Manual de usuario   CG161 LAWN TRACTOR, 98 paginas
Magna 250 Instrucciones de operaciones     Ransomes Magna 250 Operating instructions, 68 paginas
Parkway 2250 Plus Instrucciones de operaciones   Ransomes Parkway 2250 Plus Operating instructions [en] , 46 paginas
36 HYDRO Z-CONTROL MID-16HP KAW REAR DISCHARGESELF PROPELLED WALK BEHIND MOWER Manual del operador   Ransomes 36 HYDRO Z-CONTROL MID-16HP KAW REAR DISCHARGESELF PROPELLED WALK BEHIND MOWER Operator`s manual, 64 paginas
36 HYDRO Z-CONTROL MID-16HP KAW REAR DISCHARGESELF PROPELLED WALK BEHIND MOWER Manual del operador   Ransomes 36 HYDRO Z-CONTROL MID-16HP KAW REAR DISCHARGESELF PROPELLED WALK BEHIND MOWER Operator`s manual, 28 paginas